Important use note

Structural calculations, wind loads, the load-bearing substrate, on-site pull-out tests, thermal/fire/moisture design, current manufacturer data sheets and designer approval govern every project. Dimensions and performance values shown here must be verified against current documents before ordering or installation.

01 / Current main reference

21.5 cm clinker + 13+5 mm GRC

The current specification on the GRC Board website describes a system based on 215 × 65 × 15 mm clinker, a 13+5 mm board and a 605 × 1250 mm panel. C2TE class is referenced for the adhesive. This information is a starting point for quotation and preliminary design; connection layouts and subframe sections are calculated for each building.

Defining product information for the current main system
ComponentReference descriptionProject check
Klinker215 × 65 × 15 mmColour, weight, frost resistance, water absorption and batch sample
GRC Board605 × 1250 mm; 13 mm backing + 5 mm grooveCurrent product data sheet, test report, cutting and screw layout
AdhesiveC2TE reference for external façadesCompatibility with GRC and the selected clinker, temperature and open time
Grout8–12 mm; typically 10 mmWater ratio, waiting time and mock-up area in accordance with the product data sheet
SubframeAluminium profiles, brackets and mechanical connectionsWind calculation, building height, substrate type and on-site pull-out test
The 8+6 mm option requires separate documentation

The detailed source specification describes the 13+5 mm board. The same performance table must not be applied automatically to the 8+6 mm product option; request the current technical data sheet for that product.

02 / Archive — outside the price calculator scope

44 cm clinker project type

Panel System Specifications 1 and 2 in the Klinker Tuğla archive were prepared for 440 × 65 × 15 mm clinker and an approximately 18 mm (13+5) board. This system must not be merged with the 21.5 cm main system above or treated as a direct equivalent of the current price calculator.

Archived technical value declaration

The values below are manufacturer declarations transferred from an older specification; they are not presented as an independent current test report. Current product data sheets and the relevant classification/test documents must be required at ordering and project acceptance.

Archived specification values for the 13+5 mm board
PropertyArchived declarationAcceptance note
Compressive strength30–50 N/mm²Verified with a current product test report
Flexural strength8–20 N/mm²Section and test standard are confirmed
Density1,7–2,2 g/cm³Production batch and technical data sheet govern
Water absorption%7–9Current test method and report are required
Thermal conductivity0,6–1,4 W/mKDesigner approval is required for thermal calculations
Impact resistance5.000–16.000 J/m²Product and test conditions are verified
Expansion%0,58Assessed together with joint and connection calculations
Water-vapour diffusion resistance60A current value is used in moisture calculations
Reaction to fireA1 — DIN 4102 reference in the archiveA current TS EN 13501-1 classification document is required
Limit of the fire declaration

The A1 designation describes only the reaction-to-fire class of the documented GRC board. It does not automatically mean “A1” or a specific fire resistance for the adhesive, membrane, insulation or the complete façade system.

03 / System components

How should it be defined in the specification?

Control matrix for material selection and project approval
ItemSpecification approachRequired documentation
GRC boardDimensions and section suitable for the project type; 13+5 mm main referenceProduct data sheet, quality/test reports, batch and delivery records
Klinker21.5 cm main system or separate 44 cm project typeSample approval, dimensional tolerance, water absorption and freeze-thaw documentation
Adhesive21.5 cm main system: C2TE; 44 cm archived system: C2TCompatibility with the GRC substrate and clinker, open time and manufacturer installation data sheet
GroutCement-based wide-joint grout suitable for clinkerColour sample, application temperature, water ratio and curing conditions
Profiles and bracketsSection, grid and alloy are determined by project calculationsStructural calculation, corrosion conditions, fabrication drawing and supply documentation
Anchors and screwsMechanical fixing suitable for the load-bearing substrate and loadsOn-site pull-out test, anchor plan, torque and installation records
Insulation and membraneSelected according to thermal, fire and moisture designThickness/density calculation, fire documentation, laps and drainage detail

The 50 × 70 × 2 mm T-profile, 3.2 mm L-bracket, M10 × 85 anchor, 5.5 × 25 screw, 62.5 cm profile grid, 1000/1500 mm bracket spacing, 60 mm mineral wool and 90 g/m² membrane values in older documents are example descriptions from the source projects only. They must not be used as fixed rules for every building.

04 / Installation and acceptance

Site installation principles

  1. Survey and measurement: The load-bearing substrate, plumb, openings, building height, wind zone and anchoring capacity are recorded.
  2. Calculations and drawings: Profile grids, bracket/anchor layout, fixed/sliding points, corners, windows, parapets, sills, movement joints and drainage details are approved.
  3. Insulation and moisture layer: Project-suitable insulation is installed continuously; membrane laps and tapes are applied in accordance with the manufacturer’s data sheet.
  4. Subframe: Brackets and vertical profiles are installed on the calculated grid; plane, connections and corrosion conditions are checked.
  5. GRC Board installation: Board joints are resolved on supporting grid lines; screw edge distances, joint gaps and the fixed/sliding connection layout follow the approved fabrication.
  6. Mock-up area: Appearance, adhesion and cleaning methods for clinker, adhesive and grout are approved before proceeding with the entire façade.
  7. Clinker and grout: Adhesive is applied without exceeding its open time; joint width is maintained and the surface is cleaned according to the manufacturer’s instructions.
  8. Handover inspection: Loose elements, cracks, unfilled joints, surface contamination, drainage, terminations and movement joints are recorded.

Required in the project handover file

  • Approved façade elevations, details and structural calculation
  • Technical data sheets for GRC, clinker, adhesive, grout, insulation and membrane
  • Current reaction-to-fire classification and relevant test/quality documents
  • On-site anchor pull-out test and subframe fabrication records
  • Mock-up approval, batch/delivery records and site inspection reports

05 / Source documents

Review and download

The original sources are listed below. The archived Word files describe the older 44 cm project type and must not be used as though they were the same document as the current main system.

Move on to your project